Smart PDU 810Complete Power Control, Simplified

The Smart PDU 810 blends per-outlet metering and switching with layered protection — built for the AV rack that can't afford to go dark.

Talk To Us About The 810
Smart PDU 810

8 Outlets

Individually metered, switched and fused — every one of them.

5 Year Warranty

Including five years of full dashboard access, no licence fees.

10 Year Design Life

Industrial grade components rated −40 to +85°C.

1U Rack Space

Fanless design, silent operation.

Designed and manufactured in IndiaBIS registeredCE markedEngineered for Indian power conditions

Our latest platform in rack power distribution combines per-outlet intelligence with layered protection.

Engineered For Critical AV Infrastructure

An AV rack is only as dependable as the power feeding it. The Smart PDU 810 gives you independent measurement, independent switching and independent protection on every one of its eight outlets — so you can see exactly what each device draws, restore a locked-up unit without leaving your desk, and contain a fault to the single outlet that caused it.

Smart PDU 810 studio shot

Four capabilities define it.

Per-Outlet Intelligence

  • Measure everything. Voltage, current, power, power factor and energy consumed, measured independently on every one of the eight outlets.

  • Control everything. Switch any outlet on, off or through a timed power cycle from anywhere on the network. No more visits to the rack mid-meeting.

  • Limit per outlet. Set an individual current limit per outlet. A misbehaving device is isolated before it becomes everyone's problem.

  • Switch gently. Zero-cross switching times every operation to the mains waveform, dramatically extending relay life and eliminating switch-on surge stress.

Layered Protection

  • Six threats, handled. High voltage, low voltage, spikes, surges, electrical fast transients and ESD are all filtered and clamped before they reach your equipment.

  • Individually fused. Every outlet carries its own fuse and its own electronic over-current trip. A shorted 4 A AV device blows one fuse — it does not trip your UPS or darken the room.

  • Breaker, not fuse. A hydraulic-magnetic circuit breaker protects against fault currents and fire. Unlike a thermal breaker its trip point does not drift with ambient temperature.

  • Filtered input. Two-stage EMI filtering and two-stage surge suppression on the input, sized to protect the rack rather than merely to pass a test.

Smart PDU 810 on a rack

Manage It From Anywhere — Automatically

Zero-cross switching, per-outlet current limits, and a hardware watchdog that opens every outlet if the controller ever stops responding.

Remote And Local

  • Full dashboard. A clean, browser-based dashboard served directly from the unit. No software to install, no cloud account required, no licence to renew.

  • Wired and wireless. 10/100 Ethernet for permanent installation, plus 2.4 GHz Wi-Fi for commissioning and for rooms where pulling a cable is impractical.

  • Local display. A 16 x 2 backlit LCD shows live status, per-outlet readings and active faults at the rack. Green PWR and red ERROR indicators are readable across a room.

Autonomous By Design

  • Network-optional. If the network drops, the PDU keeps working. All protection, limits, sequencing and metering continue independently of any server, cloud or controller.

  • Ordered recovery. Configurable power-on state and staged sequencing per outlet, so a site recovers in the right order after an outage — sources first, amplifiers last.

  • Fail-safe. A hardware watchdog opens every outlet if the controller ever stops responding. Safety does not depend on software behaving.

Automation That Removes Site Visits

Every hour an engineer spends driving to a rack to press a button is an hour not spent on billable work. The Smart PDU 810 is built to make that journey unnecessary.

Scheduled and grouped

Scheduling. Turn outlets on and off by time of day. Displays and amplifiers switch off overnight and at weekends, cutting standby consumption you are currently paying for.

Scenes and groups. Define outlet groups and control them with one command. 'Room Off' drops the display, codec and DSP while the NVR and network switch stay up.

Staged sequencing. Configurable inter-outlet delay, so a rack powers up in the order the equipment expects — no thump, no stacked inrush, no tripped breaker.

Self-healing and alerting

Ping-watchdog reboot. The PDU pings a device on its own outlet and power-cycles it automatically if it stops responding. Unattended and remote sites recover themselves.

Alerts that reach you. Email, webhook and SNMP trap notification on any fault — over-current, over-temperature, blown fuse or lost outlet. You hear about it before the client does.

Energy export. Download per-outlet consumption as CSV for facilities reporting, ESG returns or chargeback, without anyone reading a meter.

Secure Enough For The Corporate Network

A network-connected power device now passes through IT security review before it is allowed onto a corporate LAN. The Smart PDU 810 is built to clear that review rather than to argue with it.

Access And Identity

Encrypted throughout.

The dashboard and API are served over HTTPS with TLS. Nothing travels the network in the clear.

Per-user accounts.

Named user accounts with role-based permissions. Operators can switch outlets without being able to change protection settings.

No shipped credentials.

There is no default password. The unit forces one to be set before it will operate — the single most common finding in a device security audit, removed by design.

Integrity And Evidence

Full audit trail.

Every state change is logged with the user, the action and the timestamp. You can answer who switched off the boardroom, and when.

Signed firmware.

Firmware images are cryptographically signed. The unit refuses anything that is not genuinely ours — important on a device that controls mains power.

Safe updates.

Updates are delivered over the network with automatic rollback, so security patching never requires a site visit or risks bricking a live rack.

Connections And Controls

Everything you touch and everything you plug in, laid out across a single 1U panel.

Front Panel

  • Hydraulic-magnetic circuit breaker, ON / OFF

  • Green PWR indicator — supply present

  • Red ERROR indicator — active fault

  • 16 x 2 backlit LCD — status and faults

Rear Panel

  • IEC C14 AC inlet with integrated fuse

  • 8 x IEC C13 outlets, numbered

  • RJ45 Ethernet, link and activity LEDs

  • Rating plate with MAC ID, BIS and CE marks

Where It Earns Its Place

Displays and DSPs

Product Specifications

Power Input & Protection

Input
100–240 V AC, 50/60 Hz, 10 A maximum
Inlet
IEC 60320 C14 with integrated fuse holder
Input fuse
T10A 250 V, 5 x 20 mm ceramic, time-lag
Circuit breaker
Hydraulic-magnetic, front-panel operated
EMI filtering
Two-stage, common-mode and differential-mode
Surge suppression
Two-stage, thermally protected
Threats mitigated
High/low voltage, spikes, surges, EFT, ESD
Earthing
Dedicated PE stud; all outlet earths bonded to chassis

Outputs & Switching

Outputs
8 x IEC 60320 C13
Per-outlet current
4 A maximum
Per-outlet fuse
6.3 A time-lag ceramic, rear-accessible
Over-current trip
Configurable electronic current limit per outlet
Switching
Electromechanical relay per outlet, zero-cross timed
Sequencing
Staged turn-on, configurable 0–10 s delay
Power-on default
Per outlet — last state, always on, or off
Fail-safe
Hardware watchdog opens all outlets

Metering

Per outlet
Voltage, current, active power, PF, energy (kWh)
Accuracy
+/-3 to 5%
System
Supply voltage, line frequency, total load
Temperature
Three internal points, plus optional external probe
External probe
Temperature and humidity, 1-Wire, 3 m lead
Update rate
1 Hz or faster
Data retention
Energy counters survive power loss
Export
CSV download of per-outlet consumption

Network & Protocols

Ethernet
10/100 Base-T, RJ45
Wi-Fi
2.4 GHz, external RP-SMA antenna
Serial
RS-485 half duplex, 3-pin terminal
Protocols
SNMP v2c/v3, Modbus TCP/RTU, REST/JSON, WebSocket, MQTT, TCP ASCII
Services
DHCP or static IPv4, mDNS, SNTP, Syslog
Firmware
Over-the-air update with automatic rollback

Automation

Scheduling
Time-of-day on and off, per outlet
Groups and scenes
User-defined outlet groups, single-command control
Ping-watchdog
Automatic power cycle on loss of target response
Load management
Configurable budget with priority-ordered shedding
Thermal protection
Configurable warn, shed and all-off thresholds

Security

Transport
HTTPS / TLS
Authentication
Named user accounts, role-based access control
First boot
Password must be set — no default credentials
Audit
Event log of every state change, user and timestamp
Firmware integrity
Cryptographically signed images

Management & Interface

Dashboard
Embedded web interface, served from the device
Licensing
None — no cloud account or subscription
Autonomy
Full protection, limits, sequencing without a network
Local display
16 x 2 backlit LCD
Indicators
Green PWR, red ERROR
Alerts
Email, webhook and SNMP trap
Sensor port
RJ11 6P4C, 1-Wire

Physical & Environmental

Form factor
1U, 19-inch rack
Enclosure
Powder-coated steel, 250 mm deep
Cooling
Passive convection — no fan
Operating ambient
0 to 45 °C
Components
Industrial grade, rated −40 to +85 °C
Design life
10 years

Compliance & Warranty

Safety
IS 13252 (Part 1) — BIS registered
CE
EN 62368-1, EN 55032 Class B, EN 55035
Radio
WPC ETA (India)
Origin
Designed and manufactured in India
Warranty
5 years, including full dashboard access
Availability
Ex-stock India

How It Compares

Two products are usually considered alongside the Smart PDU 810: an imported networked switched PDU from a global IT brand, and an imported AV power sequencer. The Smart PDU 810 was designed to do the work of both at a price closer to an unbranded basic import.

Smart PDU 810 compared with typical networked PDUs, AV sequencers, and unmanaged imports
Smart PDU 810this productBrand Anetworked switched PDUBrand FAV power sequencerUnbrandedbasic import
Per-Outlet Capability
Metering — voltage, current, power, PF, energyxxx
Remote switching, per outletxx
Configurable current limit, per outletxxx
Individual fuse, per outletxxx
Staged power-up sequencingxx
Zero-cross switchingxxx
Protection
Two-stage EMI filter and surge suppressionBasicx
Hydraulic-magnetic breakerThermalThermalx
Hardware fail-safe watchdogxxx
Automation
Time-of-day schedulingxx
Outlet groups and scenesxx
Ping-watchdog auto-rebootSomexx
External temperature / humidity probexx
Network & Integration
SNMP v2c / v3 with trapsxx
Modbus TCP and Modbus RTULimitedxx
REST/JSON, WebSocket, MQTTLimitedxx
Wi-Fi commissioningxxx
Dashboard licence feeNoneLicensedxx
Full operation with no networkPartial
Commercial
Warranty5 years2 years3 years6–12 mth
Lead timeEx-stock6–12 wk8–14 wk1–2 wk
BIS registeredVariesxx
Make in India / Class-I local supplierxxx
Engineering support in Indiaxxx
Spares held in Indiaxxx
Indicative price₹34,000₹90k–1.7L₹45–90k₹2–8k

Comparison compiled August 2026 from published product documentation and catalogues. "Brand A" denotes a typical networked switched rack PDU, "Brand F" a typical AV power sequencer, "Unbranded" a basic unmanaged import. Capability and pricing vary by model and change over time; prices are indicative, exclusive of taxes, and were current at the date of compilation.

Supplied Complete

In The Box

  • Smart PDU 810 unit

  • 19-inch rack mounting brackets, fitted

  • IEC power cord to order

  • 2.4 GHz Wi-Fi antenna

  • Spare fuse set

  • Quick start guide

Warranty & Support

  • Five-year product warranty

  • Five years of full dashboard access included

  • Firmware updates delivered over the network

  • Direct engineering support from the design team

  • Spares and service from India and the United States

Get The Smart PDU 810 For Your Rack.

Contact Us Today to Get Started.

BOOK A MEETING

Frequently Asked Questions

What makes the Smart PDU 810 different?
Independent measurement, switching and protection on every one of its eight outlets, plus full autonomous operation if the network drops.
Does it work without a network connection?
Yes. All protection, current limits, sequencing and metering continue independently of any server, cloud or controller.
What protocols does it support?
Modbus TCP, REST/JSON, WebSocket, MQTT, TCP ASCII, mDNS, SNTP, Syslog and OTA firmware updates.
How long is the warranty?
Five years, including five years of full dashboard access with no licence fees.
Can I control power-on order after an outage?
Yes — configurable power-on state and staged sequencing per outlet, so sources come up first and amplifiers last.